Free Roofer Matching Repairs, Re-Roofing, Flat & Metal Roofs Roofing Across Ottawa
Find a Roofer

Roof Ventilation and Ice Dams

Attic vents checked against the Building Code's 1/300 rule, and the heat loss that feeds ice dams at the eaves found and fixed.

Few published Ottawa prices: get written quotes Ask whether the work is done from the roof, from the attic, or both

Too few published Ottawa prices for ventilation work to quote a range. Get the vent area calculation in writing.

Find a Roofer

About Roof Ventilation and Ice Dams

Ice dams are a winter fixture on Ottawa roofs. Natural Resources Canada describes them as large masses of ice that collect on the lower edge of a roof and in the gutters. Melting snow runs down the roof, meets the ice and backs up, sometimes under the shingles and into the attic.

The cause starts inside. NRCan explains that if the attic is above freezing, it warms the roof sheathing and melts the snow in contact with the roof. A well-sealed and insulated attic gives a cool roof that generally will not have ice dams, and complicated roofs with many valleys, dormers or large overhangs are more prone to them. Ventilation helps keep the attic cold.

The 2024 Ontario Building Code sets the ventilation: an unobstructed vent area of at least 1/300 of the insulated ceiling area, or 1/150 where the slope is less than 1 in 6 or the roof is built with roof joists (Div. B, 9.19.1.2.). Vents can be roof, eave or gable-end types, spread evenly on opposite sides, with at least 25% of the area near the top of the space and at least 25% near the bottom. Baffles must leave at least 25 mm of air space, and insulation must not block the vents.

The Code also requires eave protection on shingle roofs in Ottawa, from the roof edge at least 900 mm up the slope to a line at least 300 mm inside the inner face of the exterior wall (9.26.5.1.). It limits the damage when an ice dam forms; it does not stop one forming.

There are too few published Ottawa prices for ventilation work to quote a range. Attic insulation and attic ventilation are listed measures in the City's Better Homes Ottawa loan program; check the current program rules before you count on it.

What This Work Covers

  • Vent area checked against 1/300 (or 1/150) of the insulated ceiling
  • Soffit and ridge or roof vent balance, top and bottom
  • Baffles so insulation does not block the eaves
  • Air leaks from the house into the attic
  • Eave protection at the roof edge

Ready to Get Started?

Tell us about your roof ventilation and ice dams job and we'll send it to local roofing contractors in Ottawa. They reply by email.

Find a Roofer